Legacy Oldest Meta Data is not populating on Capture Summary page in Security Analytics
search cancel

Legacy Oldest Meta Data is not populating on Capture Summary page in Security Analytics

book

Article ID: 405954

calendar_today

Updated On:

Products

Security Analytics

Issue/Introduction

After upgrading to Security Analytics 8.3.1, the Legacy Oldest Meta Data is not populating on the Capture Summary page when connected to the Central Manager.  If directly connected to the sensor, the data shows up correctly.

Environment

Security Analytics 8.3.1

Cause

This was caused by a condition where the 'trino' database service would continuously crash, preventing the population of the correct data.

Resolution

This has been fixed in Security Analytics 8.3.1 NSR-1, which is available by going to the "My Download" section in the Support Portal and selecting Security Analytics and then version 8.3.1.