Attempting to run the SAMPJCL member DCM70RCM to RECEIVE SYSMODs into the GLOBAL CSI
fails with
GIM54701E ** ALLOCATION FAILED FOR SMP00001 - IKJ56228I DATA SET CAI.CAZNF10.F1 NOT IN CATALOG OR CATALOG CAN NOT BE
ACCESSED.
GIM39101E ** SYSMOD CAZNF10 WAS NOT RECEIVED BECAUSE AN ERROR OCCURRED DURING SMPTLIB DATA SET PROCESSING.
GIM54701E ** ALLOCATION FAILED FOR SMP00001 - IKJ56228I DATA SET CAI.CBAPF10.F1 NOT IN CATALOG OR CATALOG CAN NOT BE
ACCESSED.
GIM39101E ** SYSMOD CBAPF10 WAS NOT RECEIVED BECAUSE AN ERROR OCCURRED DURING SMPTLIB DATA SET PROCESSING.
GIM20501I RECEIVE PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 08.
DCM70RCM is meant to be run to receive maintenance PTFs not base product FMIDs.
The customer was able to get the RECEIVE job to completed successfully by unpaxing all data from SMPREL and stored as CAI.**.F*