Seeing wrong data in the data masking tags of columns with multiple tags after scanning the datamodel and selecting scan level as 'scan by column name and data'.
Steps to replicate the scenario:
Step 1: Select a data model and scan it.
step 2: Perform PII scan on the data model
Step 3: Select classifier
Step 4: Select scan level as 'scan by column name and data'.
step 5: Compete PII scan.
step 6: Select a table having multiple PII tags on a same column.
Step 7: Hover the mouse on one of the tag of a column and can see the sample data present in it.
step 8: Hover the mouse on the other PII tag of the same column and we still see the old data.
e.g: suppose column A has 2 tags customer_no and full_name added to it. Hover on customer_no tag and we see sample customer numbers, then hover the mouse on the full_name tag but we still see the customer numbers in stead of full names which is not as per the expected behavior. Again hover the mouse on the pii tag of another column, can see the data present in that column. Then again hover mouse on the full_name tag of column A and can see full names.
TDM Version 4.11.2028
Identified as product defect.
Download and apply below patch build to resolve the reported issue:
https://ftp.broadcom.com/user/downloads/pub/TDM/TDMWeb/TDMWeb-4.11.2031.0.zip
https://knowledge.broadcom.com/external/article?articleId=10931