Using the Event Configuration Editor, add the following lines to the 0x6330000 – 0x6330075 event codes:
User_Tag1: {S 113} User_Tag2: {S 114}
Navigate to the VNM Model in the OneClick Console. In the component detail Information tab, expand the SpectroSERVER Control sub-view and click the Update Event Configuration button.
On the OneClick webpage, click on the Administration link. Select “Update Event and Alarm Files” and click on the Reload button. When the next Nimsoft trap comes in you will see the User_Tag1 and User_Tag2 varbinds mapped in the Spectrum events.