- A vSAN storage policy has been created and verified as compatible with the existing vSAN datastore in vCenter.
- When trying to create a storage profile in Aria Automation and when selecting that specific vSAN policy, the datastore does not show as an available option.
- The datastore does show as an option when using the default policy.
8.16.0
8.18.0
The grouplink for the datastore was not correctly associate in Aria Automation.
Workaround:
- Update the "Description" of the storage policy in vCenter.
- Let Aria Automations subsequent data-collection complete.