When trying to run the TSSRCVR1 job with a date and time specified, the following error occurs indicating that symbol data was not used:
1 //TSSRCVR1 JOB MSGLEVEL=1
2 //STARTING EXEC TSSRCVR1,DATA=DATE(25174)
2 IEFC657I THE SYMBOL DATA WAS NOT USED
The Time & Date are specified in the //TSSRCVR1 EXEC statement as PARM='&TME,&DTE'.
For example, the Top Secret 16.0 CAKOJCL0 library has the following sample jcl in member TSSRCVR1:
//TSSRCVR1 PROC PRINT='*', /* SYSOUT O/P DESTINATION */
// HL='CAI.TSS160', /* HIGH LEVEL QUALIFIER *
// SYSDA=SYSDA, /* LOCAL DASD DEVICE */
// DTE=DATE(YYDDD), /* DATE PARAMETER REQUIRED */
// TME= TIME(HHMM) /* TIME PARAMETER OPTIONAL */
//*********************************************************************
//* *
//* CA TOP SECRET SECURITY RECOVERY PROCEDURE (PHASE 1) *
//* *
//* CUSTOMIZE THIS PROC AS FOLLOWS: *
//* *
//* . TAILOR THE PROC STATEMENT TO MEET YOUR SITE STANDARDS *
//* *
//* REFER TO THE CA TOP SECRET INSTALLATION GUIDE FOR *
//* FURTHER INFORMATION. *
//* *
//*********************************************************************
//TSSRCVR1 EXEC PGM=TSSRECVR,PARM='&TME,&DTE'
//RECVPRT DD SYSOUT=&PRINT
//RECVFILE DD DISP=SHR,DSN=&HL..RECFILE
//RECVCMDS DD DISP=(,CATLG),DSN=&HL..CHANGES,
// UNIT=&SYSDA,SPACE=(CYL,(5,1),RLSE),DCB=BLKSIZE=3200