Intertest with COBOL 6.4 "Non Zero return code from IN25CSTA - exiting"
search cancel

Intertest with COBOL 6.4 "Non Zero return code from IN25CSTA - exiting"

book

Article ID: 403864

calendar_today

Updated On:

Products

InterTest - Batch InterTest - CICS

Issue/Introduction

Upgraded COBOL from 6.3 to 6.4 then encounter errors in Intertest 11..0

*****
+Non Zero return code from IN25CSTA - exiting

IN25COB2 V11.0 OBOL63) - 11/12/2019 16.17                                                                                      

SYM036 PASSED PARAMETER STATEMENTS                                                                 

PBHLGNC1,CUTPRINT=ALL,LISTER=REF                                                                   

SYM099 PBHLGNC1 MAXPGMVER WAS REACHED - OLDEST VERSION HAS BEEN DELETED TO PROCESS CURRENT REQUEST.

SYM010 PROCESSING HAS BEGUN FOR PROGRAM - PBHLGNC1                                                 

SYM006 LISTER=REF    REQUESTED                                                                     

SYM007 CUTPRINT=ALL    REQUESTED                                                                   

SYM023 POST-PROCESSOR TERMINATED
*****

Environment

Intertest with COBOL V6R4

Resolution

Per Intertest Batch Compatibility matrix page, PTFs are available for COBOL V6R4 support i.e.

COBOL V6R4 : PTFs
*****
InterTest Batch 11.0
Fix Category: CA.TargetSystem-RequiredService.Enterprise.COBOL.V6R4
InterTest Batch Component (CAMRB00)
LU06403
*****

For COBOL 6.4 support the following PTFs are required based on the product FMID applied:
*****
LU06402
ADD SUPPORT FOR COBOL 6.4
CABAB00
Intertest CICS
 
LU06403
ADD SUPPORT FOR COBOL 6.4
CAMRB00
InterTest Batch Component
 
LU06404
ADD SUPPORT FOR COBOL 6.4
CARXB00
CA-SYMDUMP BATCH
 
LU06405
ADD SUPPORT FOR COBOL 6.4
CAVHB00
Common Symbolic Component
*****

From this message reported:
IN25COB2 V11.0 OBOL63) - 11/12/2019 16.17     
That version/timestamp of IN25COB2 is not certified for COBOL 6.4.
Fix LU06405 ships a later version of IN25COB2 for COBOL 6.4 support where the timestamp is "06/27/2022 06.11"
Therefore it appears that the COBOL 6.4 PTFs are not applied.

See InterTest Batch MVS 11.0 Solutions page.
Using 100 items per page (bottom left). On page 3 there are the 4 COBOL 6.4 PTFs, LU06402, LU06403, LU06404, LU06405 published in July 2022.

Check maintenance levels and apply the above PTFs based on the product FMID applied.