CCSR067I COMPLETION CODE U3999 REASON CODE 00000010
search cancel

CCSR067I COMPLETION CODE U3999 REASON CODE 00000010

book

Article ID: 403781

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

Sysview for Db2 abended: CCSR067I COMPLETION CODE U3999 REASON CODE 00000010

Datacollector shows:

CCSR010E NMSPRMVC U3999 at 28D67B14 LMOD CCS@ZE01 CSECT @ZE0008
CCSR021I OWNER = ZIIP BLACK-BOX R1903                   
CCSR022I MODULE = @ZE0008 FMID = ???????? RMID = LU05332
 

Environment

z/os DB2

Cause

The abend in the Datacollector

CCSR010E NMSPRMVC U3999 at 28D67B14 LMOD CCS@ZE01 CSECT @ZE0008
CCSR021I OWNER = ZIIP BLACK-BOX R1903                   
CCSR022I MODULE = @ZE0008 FMID = ???????? RMID = LU05332

matches the symptoms for Ptf LU05332 which is a common services ptf. Sysview for DB2 is only a victim and thus a case should be opened for common services.

Resolution

This needs to be resolved with Common Services. A workaround is to turn off Ziip processing in the Datacollector though given this should be a very rare event it can be treated as a one and continue to use Ziip in the Datacollector