After replacing the battery on a Integrated RAID Controller. Several Errors are reported in the vSphere UI that indicate the local storage is inaccessible.
“System logs on host <hostname> are stored on non-persistent storage.”
Failed to access Local data store
Failed to access path /vmfs/volumes/<Datastore UUID>/<Folder>
Operation failed!
Target: <Datastore Name>
System logging is not configured on host <Hostname>
Status: A general System Error Occurred : Input/output error
VMware vSphere ESXi 7.0
The controller is still reporting a fatal error and also that there are memory/battery problems with the controller. This means that the controller is not healthy and in a fully operational state.
ESXi : /var/log/vmkernel.log
####-##-##T##:##:##.###Z cpu29:2097808)lsi_mr3: megasas_hotplug_work:615: Host bus scan completed
####-##-##T##:##:##.###Z cpu15:2097809)lsi_mr3: mfiFaultDetect:4731: Firmware in fault state. Fault code 0xff0000 Subcode 0x8000
####-##-##T##:##:##.###Z cpu15:2097809)WARNING: lsi_mr3: fusionReset:4408: megaraid_sas: resetting fusion adapter. mandateOCR flag 0x0
####-##-##T##:##:##.###Z cpu29:2097808)lsi_mr3: megasas_hotplug_work:487: lsi_mr3: Event : Controller encountered a fatal error and was reset
####-##-##T##:##:##.###Z cpu29:2097808)lsi_mr3: megasas_hotplug_work:487: lsi_mr3: Event : Controller cache discarded due to memory/battery problems
Contact your hardware vendor.