High number of alerts for voltage sensor alarm
search cancel

High number of alerts for voltage sensor alarm

book

Article ID: 402437

calendar_today

Updated On:

Products

VMware Smart Assurance

Issue/Introduction

Smarts is using MIB threshold values of a vendors device instead of the threshold values set in the Environment settings.

Environment

All support releases of Smarts

Cause

The thresholds set in Thresholds --> System Resource Groups --> <respective group> --> Environment is not honored as UseMIBThresholds is set to true. PFB screenshot for reference:

Resolution

You can set your own threshold value, and disable the MIB value of a vendors device by setting UseMIBThresholds to false in Thresholds --> System Resource Groups --> <respective group> --> Environment followed by reconfigure.