Issue/Introduction

IDMS startup getting error DC390003 after warmstart messages

DC390009 Vnn STARTING IDMS-CV/DC INITIALIZATION - 19.00.08
DC391511 Vnn Lock Manager for Warmstart initialization Complete
DC202001 Vnn Starting WARMSTART
DC202004 Vnn WARMSTART bypassed - IDMS Inactive
DC391512 Vnn Lock Manager for Warmstart terminated
DC390003 Vnn INSUFFICIENT REGION SIZE, STARTUP ABORTED.
 09.29.09 STC38580  IEA995I SYMPTOM DUMP OUTPUT  069
    069               USER COMPLETION CODE=3994

The next message would have been:

DC040101 Vnn LOCK MANAGER STORAGE ESTIMATE =  xxxx

Environment

Release: 19.0

Cause

Specifying a very large value for SUBTASKS parameter in the PARM statement which requires a lot of storage:

    PARM='MT=N,SUBTASKS=50

In this case this is used to specify the number of utility subtasks for the IDMS MQ Adapter.

 

Resolution

Apply PTF LU16711 if not already applied.

 Specify a lower value for SUBTASKS like 3 or 4.