We tried to upgrade our model from 8.7.0 to 8.7.4 and got function check error. Joblog shows messages like
Message . . . . : Function check. Y2E0704 unmonitored by YAPYPTF874 atstatement *N, instruction X'0150'.
Cause . . . . . : An escape exception message was sent to a program which
did not monitor for that message. The full name of the program to which the
unmonitored message was sent is YAPYPTF874 . At the time the message was
sent the program was stopped at higher level language statement number(s) .
If more than one statement number is shown, the program was a bound program.
Optimization does not allow a single statement number to be determined. If
*N is shown as a value, it means the actual value was not available.
Recovery . . . : See the low level messages previously listed to locate
the cause of the function check. Correct any errors, and then try the
request again.
...Message . . . . : 1 objects duplicated.
Cause . . . . . : All the objects with supported object types specified on
the Create Duplicate Object (CRTDUPOBJ) command were duplicated. See low
level messages to determine if any objects were not duplicated
CA 2E 8.7 and higher, upgrading to 8.7.4
your model uses constants MS or MT
DE636178
Please open a support case with Broadcom Support so Broadcom Support can review and provide you the fix.