Not seeing Current Queue Depth for MQ monitoring, we can see the queue but not all the details
Agent logs show the error:
[ERROR] [IntroscopeAgent.MQPcfClient] PcfClient:Failed in processInquireQueueResponse:com.ibm.mq.headers.pcf.PCFException: MQJE001: Completion Code '2', Reason '3015'.
DX O2 on-premises after 24x agent release.
MQ running on Z/os environments.
We have redesigned the MQ IA extension and as we didnt have the Mainframe setup it was not certified in the Z/OS environment.
Coming to the errors, main error 3015(MQRCCF_CFST_PARM_ID_ERROR) is coming on Z/OS because in Z/OS PCF response extra MQBACF_RESPONSE_ID attribute is coming without QueueName/ChannelName that is causing the issue.
A fix of this issue will be delivered by mid-November 2025.
As a workaround, please use Agent 20.x release, which contains this communication protocol.