DRS powered on a VM which is in powered-off state afer the snapshot consolidation
search cancel

DRS powered on a VM which is in powered-off state afer the snapshot consolidation

book

Article ID: 399828

calendar_today

Updated On:

Products

VMware vCenter Server

Issue/Introduction

  • DRS powered on the VM which was in powered-off state after the consolidation went through
    Note:Validated that the DRS powered on the VM from the VM tasks/Events

Environment

  • VMware vCenter Server 7.x
  • VMware vCenter Server 8.x

Cause

  • DRS was set to fully automated mode on the cluster with individual virtual machine automation enabled on the Cluster
  • DRS powered on the VM because After consolidation, DRS interpreted the VM as eligible for restart and that it should be powered on and balanced.

Resolution

  1. Go to the Cluster >DRS >Edit > Disable individual virtual machine automation
    Note:For more info, refer to Set a Custom Automation Level for a Virtual Machine