Objects are not receiving data from adapter instance, but it does not specify which devices are affected.
When an object that normally receives data from an adapter during a collection cycle does not receive data in the latest collection cycle, the Instance Generated|Number of No Data Receiving Objects metric for the adapter instance is changed.
The alert is triggered against an adapter when the Number of No Data Receiving Objects metric is > 0 by default.
Navigate to Alerts.
VCF Operations > Infrastructure Operations > Alerts
Aria Operations > Operations > Alerts
Click on the Alert column for the Objects are not receiving data from adapter instance alert to view the alert details
Note the Number of No Data Receiving Objects metric value in the Alert Basis > Symptoms panel.
Use the Show Objects link at the top of the page to review an Inventory view of the specific object(s) not receiving data.
Review the identified objects in the Data Source that is collected by the adapter instance
If no issues are identified in the Data Source, return to the Inventory view of the object(s) not receiving data in the UI
Aria Operations 8.18.x > Operations > Configurations > Inventory Management
VCF Operations 9.0.x > Infrastructure Operations > Configurations > Inventory Management
VCF Operations 9.1.x > Operate > Administration > Configurations > Inventory Management
Select the object(s) and click the Start Maintenance button.
Select the I will return to end maintenance myself radio button and click OK
Note: Alternatively, in the maintenance window, select a specific duration (e.g., two minutes) for the auto-end timer and click OK.
The system automatically exits maintenance after the timer expires and triggers a fresh reconciliation of the object's status.
Wait 5-10 minutes for this process to complete.
Click the Deselect All button
The following KBs identify some known issues that can cause the alert to falsely trigger for specific object types from specific adapter instances: