An Administrator will observe "Lost access to volume" events in vCenter, VMs may also crash or go unresponsive
ESXi (All versions)
DellEMC PowerFlex
On the ESXi host, in /var/log/vmkernel.log will show entries from the DellEMC PowerFlex driver stating a "IO_HARD_ERROR", which translates to a hardware error:
2025-05-12T07:52:49.524Z cpu69:2098268)WARNING: PowerFlex mapVolIO_Do_CK:1510 :Mit: 0x45d9b80e2740. Vol ID 0x########00000003. Last fault Status IO_HARD_ERROR(20).Last error Status TIMEOUT(68) Retry count (5) chan (307)2025-05-12T07:52:56.786Z cpu43:2098268)WARNING: PowerFlex mapVolIO_Do_CK:1510 :Mit: 0x45b9f049b3c0. Vol ID 0x########00000004. Last fault Status IO_HARD_ERROR(20).Last error Status TIMEOUT(68) Retry count (1) chan (307)2025-05-12T07:52:57.090Z cpu43:2098268)WARNING: PowerFlex mapVolIO_Do_CK:1510 :Mit: 0x45b9ecaed340. Vol ID 0x########00000008. Last fault Status IO_HARD_ERROR(20).Last error Status TIMEOUT(68) Retry count (1) chan (10)
Alongside these DellEMC PowerFlex specific events from their driver, there will also be entries from ScsiDeviceIO stating CHECK CONDITION, HARDWARE ERROR:
2025-05-12T07:52:45.823Z cpu41:2098472)ScsiDeviceIO: 4176: Cmd(0x45d9a58c7788) 0x2a, CmdSN 0xffffb706217de5e0 from world 2116019 to dev "eui.########################00000003" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x4 0x0 0x02025-05-12T07:52:49.524Z cpu40:2098472)ScsiDeviceIO: 4176: Cmd(0x45d9ce0c2d08) 0x2a, CmdSN 0xffffb7061e294cb0 from world 2116019 to dev "eui.########################00000003" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x4 0x0 0x02025-05-12T07:52:49.524Z cpu40:2098472)ScsiDeviceIO: 4176: Cmd(0x45d998685288) 0x2a, CmdSN 0xffffb70615627690 from world 2116019 to dev "eui.########################00000003" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x4 0x0 0x0
Contact DellEMC PowerFlex support for assistance in root causing these events. In this particular instance, there was a failed physical hard drive in the DellEMC PowerFlex solution.