Getting error, "VCF Business Services console Test Failed due to "Http failure response for https://<FQDN>/api/v1/run_uploader: 500 OK" while testing Connection with VCF Business Services console portal"
search cancel

Getting error, "VCF Business Services console Test Failed due to "Http failure response for https://<FQDN>/api/v1/run_uploader: 500 OK" while testing Connection with VCF Business Services console portal"

book

Article ID: 398932

calendar_today

Updated On:

Products

VMware Usage Meter

Issue/Introduction

Usage Meter is unable to send data to the VCF Business Services console portal (formerly known as Cloud Partner Navigator - CPN) and fails with below error: 
"Http failure response for https://<FQDN>/UM/api/v1/run_uploader: 500 OK". Please open a ticket with Broadcom support at https://support.broadcom.com/." for VCF Business Services console.
 
Upon performing connection request with curl command, and it is successful.
curl -kv https://eapi.broadcom.com/vcf/ums/api/v2/data/9.0
 
/var/log/vmware-um-platform/dss_error.log
Caused by: javax.net.ssl.SSLPeerUnverifiedException: Hostname UsageMeter_FQDN not verified:
    certificate: sha256/xxxxxxxxxxxx/c=
    DN: CN=UsageMeter_FQDN,O=local,ST=Some-State,C=US
    subjectAltNames: []

When navigating to Usage Meter UI > Cloud / Cloud Foundation > vCenter, a connection error is displayed for vCenter usage collection.

Environment

VCF Usage Meter 9.0
 
Usage Meter 4.8

Cause

Usage meter certificate is missing Subject Alternative Name as per X.509 v3 standard.

Resolution

Required to secure a snapshot of the Usage Meter appliance and follow the below steps: