Log Analyzer LADXTRCT data set RECFM changing from FS to U resulting in IEC141I 013-34 error when used as input.
search cancel

Log Analyzer LADXTRCT data set RECFM changing from FS to U resulting in IEC141I 013-34 error when used as input.

book

Article ID: 39886

calendar_today

Updated On:

Products

Log Analyzer for DB2 for z/OS

Issue/Introduction

Log Analyzer for Db2 for z/OS (PLA) reporting job abends with SYSTEM COMPLETION CODE=013 REASON CODE=00000034
when using LADXTRCT written to a tape data set as input. The LADXTRCT data set RECFM appears to be changing from FS to U.

Symptoms:

IEC141I 013-34
SYSTEM COMPLETION CODE=013 REASON CODE=00000034

Cause

Incorrect LOGSRC option specification within the PLA control cards. 

Resolution

The PLA control cards specified LOGSRC = (GROUP) which was not expected if the intent is to use an existing
Extract data set as input.  Expected LOGSRC = (EXTRACT) to be specified in the PLA control cards. 
The PLA LOGSRC control card was modified to specify EXTRACT which resolved the problem.