CA-24X7 High-Availability Manager for DB2 for z/OS CA-Batch Processor Compile QQF CA Data Compressor for DB2 for z/OS Data Navigator for DB2 UDB for z/OS CA-DB Delivery for DB2 CA Unicenter NSM CA Log Compress DBA for DB2 Guide Online CA InfoRefiner Advantage InfoRefiner Advantage InfoRefiner Maint Upgrade CA InfoTransport Advantage InfoTransport Maint Upgrade Online Reorg for DB2 for z/OS CA RC/Update for DB2 for z/OS Query Analyzer RI Editor for DB2 for z/OS DB2 TOOLS- DATABASE MISC

Issue/Introduction

Problem:

CA Log Analyzer for DB2 for z/OS (PLA) reporting job abends with SYSTEM COMPLETION CODE=013 REASON CODE=00000034 when using LADXTRCT written to a tape data set as input.  The LADXTRCT data set RECFM appears to be changing from FS to U.

Symptoms:

IEC141I 013-34
SYSTEM COMPLETION CODE=013 REASON CODE=00000034

 

Cause:

Incorrect LOGSRC option specification within the PLA control cards. 

 

Resolution:

The PLA control cards specified LOGSRC = (GROUP) which was not expected if the intent is to use an existing Extract data set as input.  Expected LOGSRC = (EXTRACT) to be specified in the PLA control cards.  The PLA LOGSRC control card was modified to specify EXTRACT which resolved the problem.

Environment

Release:
Component: PLA