Wa(180) vmkwarning: cpu##:2098914)WARNING: NMP: nmp_PathDetermineFailure:3536: Cmd (0x8a) PDL error (0x5/0x25/0x0) - path vmhba#:C#:T#:L# device naa.############################# - triggering path failover
Wa(180) vmkwarning: cpu##:2098331)WARNING: NMP: nmpDeviceAttemptFailover:644: Retry world failover device "naa.#############################" - issuing command 0x45ba8165cb40
In(14) vobd[2098150] [scsiCorrelator] 4635641116859us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device naa.############################# degraded. Path vmhba#:C#:T#:L# is down. Affected datastores: Unknown.
In(14) vobd[2098150] [scsiCorrelator] 4635649117414us: [esx.clear.storage.redundancy.restored] Path redundancy to storage device naa.############################# (Datastores: Unknown) restored. Path vmhba#:C#:T#:L# is active again.
VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x
The storage array is briefly and intermittently reporting devices to be permanently unavailable on specific paths, without the device entering a PDL state on all paths. As such path redundancy is temporarily degraded and path failover is triggered.
Engage the storage vendor to investigate the cause of the device becoming temporarily unavailable (PDL status) on specific paths