NSX Manager cluster is down, UI is not accessible with error code 101
search cancel

NSX Manager cluster is down, UI is not accessible with error code 101

book

Article ID: 398178

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

  • NSX UI is not accessible and shows the following error
    Error:
    Some appliances components are not functioning properly.
    Components health: Unknown
    Error code: 101
  • NSX Manager post failover with SRM not accessible.
  • The "get managers" command from the NSX Manager nodes indicates that all nodes are connected.

    host######> get managers
    -##.##.##.1 Standby
    -##.##.##.2 Connected 
    -##.##.##.3 Connected
  • However, "get cluster status" shows error "% An error occurred while getting the cluster status"
    nsxmanagernode> get cluster status
    % An error occurred while getting the cluster status
  • All the services on the nodes are up.
  • All the nodes can ping each other.
  • You will see the following message in the following log file, var/log/cbm/cbm.log
    YYYY-MM-DDTHH:MM:SS.###Z INFO pool-17-thread-5 ClusterConfigurationManager 3254 - [nsx@6876 comp="nsx-manager" level="INFO" subcomp="cbm"] allConfigRecords size = 0

Environment

VMware NSX

Cause

The entry 'allconfigrecords size = 0' in the cbm.log indicates that the cluster configuration is missing. As a result, the Cluster Boot Manager (CBM) is unable to start due to the absence of required configuration data.

Resolution

If you believe you have encountered this issue, please open a support case with Broadcom Support and refer to this KB article.