Large number of logging events are generated in the vsanmgmt.log from vsand process when events include structured data.
search cancel

Large number of logging events are generated in the vsanmgmt.log from vsand process when events include structured data.

book

Article ID: 397269

calendar_today

Updated On:

Products

VMware vSAN VMware vSAN 7.x VMware vSAN 8.x

Issue/Introduction

Symptoms:

Large number of logging events are generated in the vsanmgmt.log from vsand process when events include structured data.  

For example, a single "message" generates 15 log entries with payload data chunked across them.  This generates a large amount of events that required extra processing by remote log hosts like Log Insight.  Because the events are stored separately, the payload data loses it's context.


vsanmgmt.log:2025-04-08T23:16:26.095Z In(14) vsand[2101688]: [opID=#######-#### VsanPerformanceManagerImpl::executeQueryNodeInfo] QueryNodeInformation result: (vim.cluster.VsanPerfNodeInformation) {
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   version = '8.0.203',
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   isCmmdsMaster = true,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   isStatsMaster = true,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   vsanMasterUuid = '64cc12c9-b8a4-a747-####-############',
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   vsanNodeUuid = '64cc12c9-b8a4-a747-####-############',
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   masterInfo = (vim.cluster.VsanPerfMasterInformation) {
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:     secSinceLastStatsWrite = 167,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:     secSinceLastStatsCollect = 168,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:     statsIntervalSec = 300,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:     statsDirectoryPercentFree = 97,
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:     verboseMode = false
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   },
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]:   diagnosticMode = false
vsanmgmt.log:2025-04-08T23:16:26.095Z In(14)[+] vsand[2101688]: }

Environment

VMware vSAN 7.x
VMware vSAN 8.x

Cause

Broadcom Engineering identified the logs formatting issue and they are actively working on a fix.

Resolution

There is currently no resolution for this issue. Broadcom Engineering is working on a fix.
Update ESXi Hosts to the new version with the fix included once released.