OVF Import Failure Due to NSX Manager NIC Disconnection
search cancel

OVF Import Failure Due to NSX Manager NIC Disconnection

book

Article ID: 397020

calendar_today

Updated On:

Products

VMware Cloud Director

Issue/Introduction

  • When attempting to import an OVF in VMware Cloud Director, the process fails with a platform error reported from vCenter and ESXi.
  • Hosts are unable to communicate, resulting in DRS imbalance and NSX resource contention.
  • OVF import fails in VCD with a platform error.
  • Host communication errors observed in logs.
  • DRS is unable to rebalance workloads.
  • NSX Managers are unreachable, affecting resource distribution and host to host networking.

Environment

  • VMware Cloud Director 10.3
  • vCenter & ESXi 7.0
  • NSX 3.2

Cause

  • The NICs on the NSX Manager VMs are disconnected, isolating the managers from the network.
  • This prevents host to host communication, causing DRS failures and NSX resource constraints.

Resolution

  • Reconnect the NICs on the NSX Manager VMs.
  • Verify host communication is restored by initiating vMotion of a VM to another compute resource.
  • Confirm that DRS rebalancing and NSX resource distribution are operating correctly.