Cannot change the host configuration. Failed to update disk partitions for /vmfs/devices/disks/naa.500a0751######### while adding disk to the vSAN disk group.
book
Article ID: 396775
calendar_today
Updated On:
Products
Issue/Introduction
Symptoms:
The following error message appears when attempting to add a capacity disk to the disk group in the vSAN cluster.
A general system error occured .Failed to reserve naa500a075.########## with exception .Failed to read vSAN intent log.Failed to compete read device /vmfs/devices/disks/naa500a075.########## bytes read 0 of 512.
Environment
VMware vSAN 7.x
VMware vSAN 8.x
Cause
Hardware read errors were detected on the underlying disk, as indicated by the smartinfo.sh output. These errors will prevent the disk from being successfully added to the vSAN disk group.
Resolution
The hardware vendor should be contacted to run diagnostics on the disk reporting the error, and the faulty disk should be replaced.