Symptoms:
After upgrading from ESXi 6.7U3 to 8.0.3 EP3, the host experienced a delay in boot process and storage was inaccessible.
Followed KB article to resolve storage accessibility issue (Slow boot after upgrading to ESXi 8.0 U3 - Timeout during iSCSI device discovery phase), even though boot process still takes a long time.
Even with the latest NIC card driver/firmware still the issue same.
VMware vSphere ESXi 8.0 U3
Issue resolved by followed the below:
=> Updated NIC firmware
=> Used of Dell OEM A004 ISO version (had A003)
=> Followed KB: https://knowledge.broadcom.com/external/article/385971/ workaround to set ISCSI static targets.
=> In addition to this we can see "echo "provMemOveride:vmware_base=120"" in /etc/sfcb/sfcb.cfg log
when echoed into the file /etc/sfcb/sfcb.cfg, modifies the configuration for SFCB (Small Footprint CIM Broker), which is the WBEM (Web-Based Enterprise Management) provider on VMware ESXi.
and try disables the WBEM service on the ESXi host:
esxcli system wbem set -e 0
after that enables the WBEM service on the ESXi host:
esxcli system wbem set -e 1