CC=4 when using DDUPDATE utility to add/copy a table in Datadictionary PROD
search cancel

CC=4 when using DDUPDATE utility to add/copy a table in Datadictionary PROD

book

Article ID: 395368

calendar_today

Updated On:

Products

Datacom Datacom/AD Datacom/DB

Issue/Introduction

Don't see any errors that explain COND CODE 0004 when trying to copy/add a table from test to production environment. The instructions are not all that clear. 

 

Cause

1000 SET Transaction in our Datacom Core 15.1 documentation indicates:

If you add a database occurrence to Datacom Datadictionary and attempt to copy the structure to PROD status without using the 1000 SET transaction to assign DATACOM-IDs to the substructure occurrences, you will receive the following message. Datacom Datadictionary then assigns a unique DATACOM-ID attribute-value to the PROD status occurrence.

 WARNING DATACOM-ID ZERO

 

Resolution

                             Datacom Datadictionary         
Security Level: 1            Maintenance Report  

   *** VERIFY WARNING MESSAGES ***
     DDWKEY0022 WARNING DATACOM-ID ZERO

DDWKEY0022 is a warning message to inform the user that the Key ID was not set for this key, and it was assigned a value when it was copied to PROD status. 

If you want to accept the assigned value, nothing further is needed. However, if you want to assign a specific value for this key's ID, you need to update the test occurrence with the desired value, then you can copy it to PROD status.