The NSX Manager URL reported on NSX-managed DVS switches in vCenter is wrong/incorrect.
VMware vCenter
VMware NSX
An incorrect PTR record for the NSX Manager VIP/IP causes this behavior.
This can be confirmed in the NSX Manager /var/log/cm-inventory/cm-inventory.log file. A message such as this will show the PTR record response to a FQDN lookup:
INFO ClusterNodeConfigListener-1-1 IpAddressUtils 86279 - [nsx@6876 comp="nsx-manager" level="INFO" subcomp="cm-inventory"] getFqdnFromIp(): returning FQDN : <NSX_VIP_FQDN> for IP: <IP Address of VIP>
Update the DNS PTR record to reflect the correct URL. Once the FQDN lookup refreshes, the vCenter UI will show the correct URL.