Detector upgraded/migrated successfully to DLP version 16.1 and we can see new detector version in Enforce server - Servers and Detectors Overview page but detector is in unknown state and Symantec DLP Detector service stops after 5 attempts of detection start.
DLP 16.1
Server's hardware before upgrade was way below hardware minimum requirements (1 vCPU) and we can see in Detector log:
WARNING: Argument number mismatch for key DETECTION.13, returned message: Intentionally restarting this process, as STARTING is taking too long processing a message in ALL_STOPPED.
INFO: UDS status changed from STARTING to ALL_STOPPED,
SEVERE: UDS has failed to start.
Once hardware specification of the detector increased to minimum required - 4 vCPU, we can have detector fully started and working with RUNNING status.