NetMaster 12.2 Automatic VSAMUPDATE gets messages like the following ones:
IAVP0203I VSAM update processing for nn elementsIAVP0201I Installing VSAM data member MOD@xxx for LUnnnnnIAVP0104E N16C09 END OF FILE OR MEMBERN16C91 ABEND S-913 OCCURRED
On NetMaster joblog there are the following messages:
ICH408I USER(USER1 ) GROUP(STARTASK) NAME(STARTED TASK USERID ) SYS25106.T235002.RA000.jobname.R0100100 CL(DATASET ) VOL(vvvvvv) INSUFFICIENT ACCESS AUTHORITY ACCESS INTENT(UPDATE ) ACCESS ALLOWED(NONE ) IEC150I 913-38,IFG0194E,jobname,step,SYSPRINT,nnnn,vvvvvv, SYS25106.T235002.RA000.jobname.R0100100
The SYSPRINT dataset name is the standard IBM one (see Data set name for temporary data set page on IBM z/OS documentation) and is not customizable on NetMaster side:
SYSyyjjj.Thhmmss.RA000.jobname.Rnnnnnnn
yy=year
jjj=julian date
hh=hours
mm=minutes
ss=second
region=region name
The only solution is allowing the USER1 userid to update those datasets.
A temporary workaround is running batch NMVIP jobs to update MODSDIS and PANLDIS.
Note that with 13.0 release the percentage of APARs/PTFs requiring automatic VSAMUPDATE (or batch NMVIP) drops to almost zero.