ESXi TN NSX configuration state in "partial success" state - failing with the error - "TransportNodeProfile has VDS configuration but HostProfileEngine did not create VDS on host post reboot before timeout."
search cancel

ESXi TN NSX configuration state in "partial success" state - failing with the error - "TransportNodeProfile has VDS configuration but HostProfileEngine did not create VDS on host post reboot before timeout."

book

Article ID: 394256

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

The host cannot be prepared for NSX as the stateful workflow is done on a stateless host. The host remains in Partial Success.

Relevant logs: 

  • NSX Manager: /var/log/proton/nsxapi.log 

2025-03-20T18:50:36.063Z  INFO TRANSPORT-NODE-MSG-REALIZATION-0 NetworkMigrationUtils 84395 FABRIC [nsx@4413 comp="nsx-manager" level="INFO" subcomp="manager"] Found TransportNode [TransportNode/########-####-####-####-########] is a stateless host.

 

Environment

VMware NSX with stateless hosts 

Cause

Stateless host not correctly identified.

 

 

Resolution

Workaround:

  1. SSH into NSX Manager [admin].
  2. Run restart cm-inventory service
  3. Reprepare host for NSX and verify installation is successful.