When running the REXX program OPSSM2CV the following abend occurs:
System abend code 0C3, reason code 00000003.
Abend in external subroutine OPSCLEDQ.
IEA995I SYMPTOM DUMP OUTPUT
SYSTEM COMPLETION CODE=0C3 REASON CODE=00000003
TIME=14.22.25 SEQ=00069 CPU=0000 ASID=003D
PSW AT TIME OF ERROR 078D1000 8860058A ILC 4 INTC 03
ACTIVE LOAD MODULE ADDRESS=08600520 OFFSET=0000006A
NAME=OPSCLEDQ
DATA AT PSW 08600584 - 00044410 C06650B0 D00850D0
AR/GR 0: 006A7710/08C87C90 1: 00000000/08CCF49C
2: 00000000/00000000 3: 00000000/00009B88
4: 00000000/08CCF190 5: 00000000/04413187
6: 00000000/00000000 7: 00000000/00000003
8: 00000000/8440A808 9: 00000000/08C84231
A: 00000000/08C87F5C B: 00000000/04412060
C: 00000000/88600520 D: 00000000/08CCF190
E: 00000000/844130A4 F: 01000002/88600520
END OF SYMPTOM DUMP
70 +++ Call Opscledq
Error running OPSSM2CV, line 70: Incorrect call to routine
The REXX OPSSM2CV uses functions like OPSCLEDQ that can only be used in OPS/REXX programs. They cannot be executed as a TSO/REXX program
When calling OPSSM2CV use the OI - OPSIMEX statement:
OI OPSSM2CV arguments