Issue/Introduction

When running the REXX program OPSSM2CV the following abend occurs:

System abend code 0C3, reason code 00000003.                     
Abend in external subroutine OPSCLEDQ.                           
IEA995I SYMPTOM DUMP OUTPUT                                      
SYSTEM COMPLETION CODE=0C3  REASON CODE=00000003                 
 TIME=14.22.25  SEQ=00069  CPU=0000  ASID=003D                   
 PSW AT TIME OF ERROR  078D1000   8860058A  ILC 4  INTC 03       
   ACTIVE LOAD MODULE           ADDRESS=08600520  OFFSET=0000006A
   NAME=OPSCLEDQ                                                 
   DATA AT PSW  08600584 - 00044410  C06650B0  D00850D0          
   AR/GR 0: 006A7710/08C87C90   1: 00000000/08CCF49C    
          2: 00000000/00000000   3: 00000000/00009B88      
          4: 00000000/08CCF190   5: 00000000/04413187      
          6: 00000000/00000000   7: 00000000/00000003      
          8: 00000000/8440A808   9: 00000000/08C84231      
          A: 00000000/08C87F5C   B: 00000000/04412060      
          C: 00000000/88600520   D: 00000000/08CCF190      
          E: 00000000/844130A4   F: 01000002/88600520      
  END OF SYMPTOM DUMP                                      
     70 +++ Call Opscledq                                  
 Error running OPSSM2CV, line 70: Incorrect call to routine         

 

Cause

The REXX OPSSM2CV uses functions like OPSCLEDQ that can only be used in OPS/REXX programs. They cannot be executed as a TSO/REXX program

Resolution

When calling OPSSM2CV use the OI - OPSIMEX statement:

OI OPSSM2CV arguments