HBA adapter showing offline, but appears to be physically healthy as the link light was active and reporting activity.
Esxi 7.0.3 build-19193900, Cisco UCS, Cisco Vic FNIC
Cisco VIC FNNIC Card on single ESXi host is not sending appropriate VPD (Vital Product Data), This was confirmed in utilizing vmkchdev command from the command line on the host.
[root@####:~] vmkchdev -l | grep vmhba0
0000:##00.# ####:#### ####:##18 vmkernel vmhba0
Adapter: vmhba0
Port ID: 000000
Node Name: ##:##:##:##:##:##:##:##
Port Name: ##:##:##:##:##:##:##:##
Speed: 0 Gbps
Port Type: NPort
Port State: OFFLINE
Model Description: none
Hardware Version: none
OptionROM Version: 1
Firmware Version: 1
Driver Name: nfnic
DriverVersion: 1
VCF GS identified that the card was not configured properly either at hardware or BIOS level to appropriately pass information to host.
VCF Administrator will need to work with the Primary Hardware Vendor to review the cards health and functionality to ensure its communicating appropriately with host. Once this is completed VCF GS can reevaluate the cards state from the host to ensure from and ESXi perspective things are configuration appropriately and communicating as expected.