After upgrading nic cards firmware and ESXi version 8 observed VSAN network partition
search cancel

After upgrading nic cards firmware and ESXi version 8 observed VSAN network partition

book

Article ID: 393799

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

After upgrading the network card firmware and ESXi host version, connectivity to other hosts via the vSAN network was lost.

  • Driver and firmware information

bnxtnet  driver: 220.0.9.0      Firmware: 223.0.205.0 

  • Nic card information

 14e4  16d7  14e4  4141  Broadcom BCM57414 NetXtreme-E 10Gb/25Gb RDMA Ethernet Controller

Environment

ESXi 8.x

Cause

  • Driver 220.0.9.0 is not compatible with ESXi 8.x due to its absence from the Hardware Compatibility List (HCL).
  • The network card's firmware and driver are out of sync.

 

 

Resolution

1. Follow the steps to Determining Network/Storage firmware and driver version in ESXi

2. Update driver and matching firmware, Please refer following link for additional information on compatibility matrix

3. verify network connectivity