Symptoms:

  • Datastores not listed under ESXi host in vSphere Client after upgrade from 7.0 U3 to 8.0 U2 (Build 23305546)

  • Qlogic HBA fails to detect:


  • iDRAC of the physical server shows the HBA healthy and good.

  • lspci command on the affected host do show the adapters being detected:

    0000:41:00.0 Fibre Channel: QLogic Corp ISP2812-based 64/32G Fibre Channel to PCIe Controller [vmhba2]
    0000:41:00.1 Fibre Channel: QLogic Corp ISP2812-based 64/32G Fibre Channel to PCIe Controller [vmhba3] 

  • One of the working ESXi host exhibits HBA being online:

Environment


vSphere 7.x

vSphere 8.x

Cause

vSphere Client fails to load the HBA modules as it fails to initialize.

Symptoms:

/var/log/boot.gz on ESXi host reports the Adapters vmhbaX and vmhbaY failing to initialize:

2025-03-27T01:02:46.272Z cpu20:2098144)qlnativefc: (41:0.0): scsi(4): qlnativefcMailboxCommand(4): **** FAILED
 mb[0]=4003 mb[1]=0 mb[2]=2 cmd=7 ****2025-03-27T01:02:46.272Z cpu20:2098144)WARNING: qlnativefc: (41:0.0): scsi(4): scsi(4): Failed to initialize adapter - Adapter flags 2.
2025-03-27T01:02:46.278Z cpu##:#######)DMA: 732: DMA Engine 'qlnativefcDMAEngine0' destroyed.

2025-03-27T01:02:47.966Z cpu20:2098144)qlnativefc: (41:0.1): scsi(5): qlnativefcMailboxCommand(5): **** FAILED
 mb[0]=4003 mb[1]=0 mb[2]=2 cmd=7 ****2025-03-27T01:02:47.966Z cpu20:2098144)WARNING: qlnativefc: (41:0.1): scsi(5): scsi(5): Failed to initialize adapter - Adapter flags 2.
2025-03-27T01:02:47.973Z cpu##:#######)DMA: 732: DMA Engine 'qlnativefcDMAEngine0' destroyed.

Resolution


Consult hardware vendor to investigate the HBA modules.