Datastore performance graph in vCenter Web Client UI indicates higher than expected latency for VMs and backend.
Vmkernel.log
YYYY-MM-DDTHH:MM:SS cpu11:2098200)ScsiDeviceIO: 3414: Cmd(0x459b7c56c880) 0x2a, CmdSN 0x800e0046 from world 2102393 to dev "naa.################################" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0xb 0x47 0x3.YYYY-MM-DDTHH:MM:SS cpu11:2098200)ScsiDeviceIO: 3414: Cmd(0x459b7c5025c0) 0x2a, CmdSN 0x800e0005 from world 2102393 to dev "naa.################################" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0xb 0x47 0x3.YYYY-MM-DDTHH:MM:SS cpu12:2098200)ScsiDeviceIO: 3414: Cmd(0x45a2cc785300) 0x2a, CmdSN 0x800e0039 from world 2102393 to dev "naa.################################" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0xb 0x47 0x3.
VMware vSphere Esxi
This error suggests a parity error condition, where the disk has not received the FC packet correctly.
The potential causes of this issue could be any component on the FC loop, such as cables, interfaces, or any other related hardware.
Contact storage vendor for assistance.