How to address the U0064 abend in CA Workload Automation Restart Options for z/OS Schedulers?

book

Article ID: 39324

calendar_today

Updated On:

Products

CA-11

Issue/Introduction

Question: 

How to address abend U0064 in CA 11?

Answer: 

U0064 is an indication that there is a GDG bias reference (+0) but there is no GDG dataset cataloged to the GDG base, or there is a GDG bias reference (+1) but there is no GDG base defined to the catalog.  At least one GDG dataset has to be catalog to for a GDG bias reference (+0).  A GDG base has to exist before a GDG bias reference (+1) dataset can be created.   After correcting the problem the job should be resubmitted for production. 

 

As always, please contact CA Technologies support for CA Workload Restart Option for z/OS Schedulers if you have further questions.

Environment

Release: ELEVEN00200-11-Workload Automation-Restart Option-for Z/OS Schedulers
Component: