Issue/Introduction

  • Alarm related to other hardware object being in error state appears without any apparent hardware failures.
  • Clearing or acknowledging alarm doesn't stop from reappearance.  
  • Checking the host management agent logs (hostd), you see periodic check reporting "Red" status for "Other" category.
    2025-03-26T00:05:30.478Z Event 12652 : Hardware Sensor Status: Processor Green, Memory Green, Fan Green, Voltage Green, Temperature Green, Power Green, System Board Green, Battery Green, Storage Green, Other Red
    2025-03-26T06:06:40.798Z Event 12988 : Hardware Sensor Status: Processor Green, Memory Green, Fan Green, Voltage Green, Temperature Green, Power Green, System Board Green, Battery Green, Storage Green, Other Red
    2025-03-26T12:07:55.324Z Event 13175 : Hardware Sensor Status: Processor Green, Memory Green, Fan Green, Voltage Green, Temperature Green, Power Green, System Board Green, Battery Green, Storage Green, Other Red

Environment

VMware ESXi 7.x

VMware ESXi 8.x

VMware vCenter 7.x

VMware vCenter 8.x

 

Cause

  • IPMI System Event logging is disabled at the board management due to event space is full or near full. 
  • Checking Sensor Data Record using command 'esxcli hardware ipmi sdr list' might show assert status for the related sensor. (Note: Availability of this sensor is hardware dependent)
    Node-Sensor  Description                                   Entity-Instance  Computed Reading   Base Unit            Raw Reading
    -----------  --------------------------------------------  ---------------  -----------------  -------------------  -----------
    0.254        System Management Software 1 SEL Fullness     33.1             SEL Almost Full    sensor-discrete      32           Event Logging Disabled
  • Alternatively, you can use the Server Management Tools like iDRAC/iLO to confirm the status of System Event logging

Resolution

Clear the System Event logging following the steps outline in  "Host IPMI system event log status" alarm in vCenter Server.