Power stats for ESXi hosts after upgrading to 8.0 U3 is inaccurate & the graph is showing flattened.
VMware ESXi 8.x
2025-01-27T23:16:07.321Z Wa(164) sensord[2101778]: [Originator@6876 sub=Default] ipmi_completion: IPMI completion code for msgid: 8982813, cc = 0xff
2025-01-27T23:16:07.321Z Wa(164) sensord[2101778]: [Originator@6876 sub=Powersvc] Failed to read Dell subsys power
2025-01-27T23:16:17.322Z Er(163) sensord[2101594]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:16:27.324Z Er(163) sensord[2102231]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:16:37.326Z Er(163) sensord[2101595]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:16:47.327Z Er(163) sensord[2102488]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:16:57.330Z Er(163) sensord[2101596]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:17:07.331Z Er(163) sensord[2101600]: [Originator@6876 sub=Powersvc] Failed to read from power provider
2025-01-27T23:17:07.331Z Er(163) sensord[2101600]: [Originator@6876 sub=Powersvc] Too many failures, powersvc offline
Based on the above logs, the powersvc provider has stopped, which would cause sensord to stop fetching power readings.
This is a known issue.
Workaround : Restart sensord so that it can start collecting the power metrics through its powersvc plugin.
/etc/init.d/sensord restart
This issue is fixed in the upcoming 8.0.3 P05 release.