Path redundancy to storage device degraded" Events are seen on vCenter.Cannot connect to storage" triggers on the ESXi host.IF Lost Storage ConnectivityOR Lost Storage Path RedundancyOR Degraded Storage Path RedundancyOR Lost connection to NFS serverTHEN trigger the alarm as unknownESXi host > Configure > Alarm Definitions./var/run/log/vobd.log file, similar entries are seen:YYYY-MM-DDTHH:MM.SSSZ In(14) vobd[2098149]: [scsiCorrelator] 6182941357us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device eui.################################ degraded. Path vmhba6:C0:T19:L0 is down. Affected datastores: Unknown.
YYYY-MM-DDTHH:MM.SSSZ In(14) vobd[2098149]: [scsiCorrelator] 6182942941us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device eui.################################ degraded. Path vmhba6:C0:T19:L1 is down. Affected datastores: Unknown.
YYYY-MM-DDTHH:MM.SSSZ In(14) vobd[2098149]: [scsiCorrelator] 6182944535us: [esx.problem.storage.redundancy.degraded] Path redundancy to storage device eui.################################ degraded. Path vmhba6:C0:T19:L2 is down. Affected datastores: Unknown./var/run/log/hostd.log file confirm that the VM power off operation gets stuck and queued up.2025-06-06T10:05:29.568Z Db(167) Hostd[2102696]: [Originator@6876 sub=Vmsvc.vm:/vmfs/volumes/########-########-####-############/VM/VM.vmx opID=########-########-auto-#####-h5:########-32-ff-#### sid=######## user=vpxuser:VSPHERE.LOCAL\Administrator] PowerOff request queued
2025-06-06T10:05:29.570Z In(166) Hostd[2102688]: [Originator@6876 sub=Vmsvc.vm:/vmfs/volumes/########-########-####-############/VM/VM.vmx] Upgrade is required for virtual machine, version: 15
2025-06-06T10:05:36.903Z Wa(164) Hostd[2102684]: [Originator@6876 sub=IoTracker] In thread 2102680, fopen("/vmfs/volumes/########-########-####-############/VM/VM.vmx") took over 392 sec./var/run/log/vmkernel.log file indicates that the vhmba link down events.YYYY-MM-DDTHH:MM.SSSZ In(182) vmkernel: cpu93:2101535)qlnativefc: vmhba6(99:0.1): qlnativefcAsyncEvent:847:NVMe report link downYYYY-MM-DDTHH:MM.SSSZIn(182) vmkernel: cpu93:2107156)qlnativefc: vmhba6(99:0.1): qlnativefcAsyncEvent:760:NVMe report link up.esxcli storage san fc events get" confirm vmhba status link down events frequently.esxcli storage san fc events get
FC Event LogYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK DOWNYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK UPYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK DOWNYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK UPYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK DOWNYYYY-MM-DD HH:MM:SS.ms [vmhba6] LINK UP"esxcli storage san fc stats get" FcStat: Adapter: vmhba6 Tx Frames: 10447376 Rx Frames: 20986931 Lip Count: 0 Error Frames: 0 Dumped Frames: 0 Link Failure Count: 168088 Loss of Signal Count: 0 PrimSeq Protocol Err Count: 0 Invalid Tx Word Count: 0 Invalid CRC Count: 0 Input Requests: 6024784 Output Requests: 30838 Control Requests: 336718
esxcli storage san fc events get to check for link flapping specific to the RDM target.