We are seeing some case of alarms that are being turned into invisible and we don't know who or what is making them invisible.
DX UIM 24.3.*
Guidance
Analyzing nas.log would provide indications on who or what is turning the alarms into invisible.
Some guidance for reding the alarm log.
First set "loglevel = 5, and "debug = 5"
Mar 3 09:07:19:718 [12876] 2 nas: NiS bridge: NTS UPDATED VISIBILITY: nimid='#########-######', FALSEMar 3 09:07:19:721 [12876] 2 nas: NiS bridge: NA UPDATED VISIBILITY: nimid='#########-######', FALSE
Line 357: Mar 3 09:10:14:958 [11848] 2 nas: ExecEvent: IMMEDIATE rule='set pollagent alarm inviisble', nimid='#########-######', ACTION:set_visibilityLine 358: Mar 3 09:10:14:958 [11848] 3 nas: ExecEvent: Rule='set pollagent alarm inviisble' on nimid=''#########-######'' with ACTION:set_visibility, age:0s, status:OK
Mar 12 10:46:31:805 [14740] 2 nas: NiS bridge: NTS UPDATED VISIBILITY: nimid=''#########-######', FALSEMar 12 10:46:31:806 [14740] 2 nas: NiS bridge: NA UPDATED VISIBILITY: nimid='#########-######', FALSE