Storage Paths missing for iSCSI based LUNs on Pure FlashArray after ESXi update
search cancel

Storage Paths missing for iSCSI based LUNs on Pure FlashArray after ESXi update

book

Article ID: 390815

calendar_today

Updated On: 04-11-2025

Products

VMware vSphere ESXi 7.0 VMware vSphere ESXi 8.0

Issue/Introduction

Symptoms: 

  • You are using Pure FlashArray SAN using ESXi Software iSCSI Adapter
  • After upgrading ESXi host, some storage paths are missing (related to one particular SAN controller)
  • We see CHAP authentication errors in vobd.log on the affected ESXi host similar to the following:

2025-03-10T16:46:24.765Z In(14) vobd[2097956]:  [iscsiCorrelator] 260657405587us: [vob.iscsi.target.login.error] vmhba64 @ vmk2 failed to login to iqn.XXXX-YY.com.purestorage:flasharray.
abcdef0123456789 because the target returned a login status of 0201

Environment

  • VMware vSphere ESXi 7.x
  • VMware vSphere ESXi 8.x
  • Pure Flash Array
  • iSCSI

Cause

  • CHAP authentication credentials no longer valid on one controller after upgrading with dynamic discovery enabled
  • Dynamic Discovery is not supported when using CHAP with Pure FlashArray

Resolution

Additional Information