Problem: e2e_appmon probe - scripts previously running fine moved to Win 2012 now return -5 error code "Unable to start (No response from e2e_starter)" alarm
e2e_appmon probe - scripts previously running fine on Windows 2008 R2 moved to Win 2012 R2 now return -5 error code "Unable to start (No response from e2e_starter)" alarm
The scripts may appear to run fine but then produce the error code.
Environment
Windows 2012 R2 observed on UIM 8.3.1 with e2e_appmon probe version 2.24
Cause
Seems to be caused by LUA scripts not enabled on Windows
Resolution
In the Windows registry editor verify the following registry key: HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\policies\system\EnableLUA = 0