WWPN change on QME2662-DEL FC adapters after Dell iDRAC update causes missing VMFS datastores
search cancel

WWPN change on QME2662-DEL FC adapters after Dell iDRAC update causes missing VMFS datastores

book

Article ID: 387601

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

Symptoms:

After upgrading the firmware of the Dell iDRAC server and rebooting the host, you may experience these symptoms:

  • VMFS datastore is missing
  • VMFS datastore cannot be accessed or browsed
  • Virtual machines are showing as Inaccessible
  • Virtual machines cannot be powered on

ESXi hosts using FC adapter model QME2662-DEL may encounter this issue.

Environment

VMware vSphere ESXi 7.x

VMware vSphere ESXi 8.x

Cause

This is a known issue where the WWPN on the QME2662 FC16 Mezz adapter changes from chassis assigned to server assigned after iDRAC is updated to version 4.00.00. This can result in connectivity to the fabric being lost and the FC HBA not being able to reach the storage target.

Reference external article: Dell Firmware DUP for Qlogic 26XX series Fibre Channel adapters. | Driver Details | Dell India

 

Resolution

To verify the model of the adapter and the WWPN on the vCenter, navigate to the ESXi host reporting the problem and select configure > Storage Adapters > Select the FC adapter and it will show the WWN and WWPN as shown in the image below:


esxcli
 command for CLI users: esxcli storage san fc list


Resolution

  1. Involve the Fiber Channel switch vendor to create a new or update the existing zone with the new WWPN address of the FC adapters.

  2. Once done, we will need to do a rescan of the adapter and the storage and the datastore should be visible again.

Additional Information

This issue was also observed in the QME2742 Dual Port 32GB Fiber Channel to PCIe Adapter after the ESXi version was upgraded.