After upgrading the firmware of the Dell iDRAC server and rebooting the host, you may experience these symptoms:
ESXi hosts using FC adapter model QME2662-DEL may encounter this issue.
VMware vSphere ESXi 7.x
VMware vSphere ESXi 8.x
This is a known issue where the WWPN on the QME2662 FC16 Mezz adapter changes from chassis assigned to server assigned after iDRAC is updated to version 4.00.00. This can result in connectivity to the fabric being lost and the FC HBA not being able to reach the storage target.
Reference external article: Dell Firmware DUP for Qlogic 26XX series Fibre Channel adapters. | Driver Details | Dell India
To verify the model of the adapter and the WWPN on the vCenter, navigate to the ESXi host reporting the problem and select configure > Storage Adapters > Select the FC adapter and it will show the WWN and WWPN as shown in the image below:
command for CLI users:
esxcliesxcli storage san fc list
Resolution
This issue was also observed in the QME2742 Dual Port 32GB Fiber Channel to PCIe Adapter after the ESXi version was upgraded.