Error Code: LCMVRAVACONFIG590024
VMware Aria Automation hostname is not valid or unable to run the product specific commands via SSH on the host. Check if VMware Aria Automation is up and running.
VMware Aria Automation hostname is not valid or unable to run the product specific commands via SSH on the host. Check if VMware Aria Automation is up and running.
/var/log/vrslcm/vmware.vrslcm.log
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.d.v.h.VraPreludeInstallHelper] -- Command to be run : vamicli version --appliance
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.d.v.h.VraPreludeInstallHelper] -- PRELUDE ENDPOINT HOST :: ########.#######.com
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.d.v.h.VraPreludeInstallHelper] -- COMMAND :: vamicli version --appliance
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- Executing command on the host: ########.#######.com, as user: root
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- ------------------------------------------------------
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- Command: vamicli version --appliance
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- ------------------------------------------------------
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- exit-status: 1
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- Command executed sucessfully
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.u.SshUtils] -- Command execution response: {
"exitStatus" : 1,
"outputData" : "Internal error. Please make sure sfcbd is running.\n",
"errorData" : null,
"commandTimedOut" : false
}
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.d.v.h.VraPreludeInstallHelper] -- Command Status code :: 1
INFO vrlcm[1584] [pool-3-thread-50] [c.v.v.l.d.v.h.VraPreludeInstallHelper] --
Aria Automation 8.x
Aria Suite Lifecycle 8.x
This error can occur if the sfcbd
service on the Aria Automation appliance is not running, even if systemctl status vami-sfcb.service
indicates that it is.
Verify sfcbd
Service Status:
vamicli version --appliance
sfcbd
is not functioning correctly.Restart sfcbd
Service:
systemctl restart vami-sfcb.service
Retry Inventory Sync:
sfcbd
service has been restarted, re-initiate the VRSLCM inventory sync.