A datastore is inaccessible. A storage fault may have occurred (e.g., a faulty device has been replaced), but the error persists at the ESXi host level.
/var/log/vmkernel.log will contain logging similar to:cpu4:2100166 opID=3daf56db)Vol3: 2204: Could not open device 'naa.################################1' for volume open: Not foundcpu4:2100166 opID=3daf56db)WARNING: ScsiDeviceIO: 12155: READ CAPACITY on device "naa.################################" from Plugin "HPP" failed. I/O errorcpu4:2100166 opID=3daf56db)WARNING: ScsiDeviceIO: 12155: READ CAPACITY on device "naa.################################" from Plugin "HPP" failed. I/O errorcpu4:2100166 opID=3daf56db)LVM: 6444: Could not open device naa.################################:1, vol [########-########-####-############, ########-########-####-############, 1]: No such target on adapter
The partition table may also appear unreadable:Device: /vmfs/devices/disks/naa.################################Partition table:Error: Error opening /dev/disks/naa.################################5: No such deviceUnable to get device /vmfs/devices/disks/naa.################################
VMware vSphere ESXi
There is a basic access issue to the device resulting in an I/O error. When the ESXi storage layer loses access to the backing VMFS storage device, it cannot read virtual machine descriptor files, forcing the kernel to register the datastore and contained workloads as inaccessible.
Before performing the resolution steps below, it is recommended to review the physical hardware layer to rule out controller-level failures. Log in to your physical server management console (e.g., iDRAC, iLO, or IPMI) and review the hardware status logs for controller panics, drive failures, or bus errors. If significant hardware issues are reported in the server logs, engage your hardware vendor to investigate the physical storage controller or disk health before performing resets.
In some cases, the storage level issue may be resolved, but the errors persist at the ESXi level. In that case, a storage rescan on the host or a host reboot may restore access to the device/datastore.
If issues persist after a storage rescan and host reboot, engage your storage vendor support to investigate further.
Note: If the issue recurs intermittently, repeated reboots may not resolve underlying hardware failure and could mask significant device degradation. It is recommended to involve your hardware or storage vendor to inspect the physical disk and controller health if the issue does not remain resolved.