[netCorrelator] 15037473322098us: [vob.net.vmnic.linkstate.down] vmnic vmnicX linkstate down
cpu33:2097231)WARNING: Uplink: 21014: Queue 0 of device vmnicX stuck, resetting the device
cpu38:2097388)nmlx4_en: vmnic5: nmlx4_en_UplinkReset - (nmlx4_en_uplink.c:2577) Watchdog process reset the uplink for port: 0x1
Hostd[2099103]: [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 26461 : Sensor 161 type temperature, Description [Device] Add-in Card 17 AOC_NIC Temp state assert for . Part Name/Number N/A N/A Manufacturer N/A
Hostd[2099103]: [Originator@6876 sub=Vimsvc.ha-eventmgr] Event 26462 : Hardware Sensor Status: Processor , Memory , Fan , Voltage , Temperature Red, Power , System Board , Battery , Storage , Other
2026-04-29T06:57:15.261Z In(182) vmkernel: cpu1:2098152)<NMLX_INF> synd 0x10: High temprature
2026-04-29T06:57:15.319Z In(182) vmkernel: cpu0:2098118)<NMLX_INF> synd 0x10: High temprature
As the queue of the vmnic adapter got stuck, the watchdog process reset the uplink. Generally, this is a recoverable state and the link state should be back up in a few seconds.
This is a condition that may occur in a VMware vSphere environment, try to resolve the issue following the steps below: