Objects in Aria Operations do not have any historical data after recent outage
search cancel

Objects in Aria Operations do not have any historical data after recent outage

book

Article ID: 387126

calendar_today

Updated On:

Products

VMware Aria Suite

Issue/Introduction

Objects in Aria Operations have been discovered, but the historical metrics are empty.

  • Clicking Validate Connection in the adapter configuration page returns Test Successful
  • The status of the adapter collecting the object's data is OK
  • There are no configurations in the adapter (including Advance Settings) limiting the data collection
  • The credential configured for the adapter has appropriate permissions to collect the data
  • There was a recent significant outage in the environment that effected the Aria Operations cluster

 

Environment

VMware Aria Operations 8.x with HA or CA enabled

Cause

A recent outage in the environment caused a split brain scenario between the primary and primary replica node in the Aria Operations cluster causing multiple duplicate objects to be created.

Resolution

  1. Navigate to the Operations > Configurations > Inventory Management page
  2. In the Type here to apply filters box, type the name of the object that has no historical data and hit Enter
  3. Review the results to determine if there are multiple objects with the same name

    Note: If no duplicate objects are seen, the next steps in the KB should NOT be used.

  4. Review the Collection State and Collection Status icons to identify the object that is currently collecting data
  5. Highlight the row of the object with data collection occurring and click the Go To Details button (graph icon)
  6. Verify that current and historical metrics are collected for this object.
  7. Return to the Inventory Management page
  8. Highlight the rows for any of the duplicate objects and click the Delete Object button (X icon)
  9. (Optional) If the relationships for the object that is collecting the data are incorrect, the adapter instance can be recreated
    1. Navigate to Administration > Integrations
    2. Click the 3 dots next to the adapter instance collecting the data for object and select Edit
    3. Note the current configuration (including Advanced Settings)
    4. Click Cancel
    5. Click the 3 dots next to the adapter instance collecting the data for object and select Delete
    6. DO NOT CHECK THE "Delete related objects" CHECKBOX!
    7. Click Delete
    8. Use the steps from the documentation to recreate the adapter instance using the details noted in step 9.c.

      Integrating Data Sources with VMware Aria Operations