PE031 error occurred in the "%INPUT DCONVERT,*" process
search cancel

PE031 error occurred in the "%INPUT DCONVERT,*" process

book

Article ID: 38684

calendar_today

Updated On:

Products

Panvalet

Issue/Introduction

The "%INPUT DCONVERT,*" job receives error "PE031 16-16 I/O ERROR PDSOUT *".


            %FETCH  PANELIB *TEST    .ELEMENT1/EXEC    ;TA                          \DECONV\
PE031 16-16 I/O ERROR PDSOUT * .UUNS6350 00000000004200000000000000000000000001C0
            %FETCH  PANELIB *TEST    .ELEMENT1/EXEC    ;TA                          \DECONV\
PE031 16-16 I/O ERROR PDSOUT * .XYSKB220 00000000004200000000000000000000000001C0


Environment

PANEXEC 5.3

Cause

PDSOUT DD points to a PDSE data set.

Resolution

PANEXEC PDSOUT DD pointing to a PDSE data set is not supported.
If you need to copy an element to the PDSE file, copy it to a PDS data set first.  Then copy from the PDS to the PDSE file using PGM=IEBCOPY.