How to resolve error message "DB90152E - DATACOM PARM SYNTAX ERROR (H)"

book

Article ID: 38678

calendar_today

Updated On:

Products

Datacom DATACOM - AD CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services Datacom/AD CA ecoMeter Server Component FOC EASYTRIEVE REPORT GENERATOR FOR COMMON SERVICES INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA On Demand Portal CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware

Issue/Introduction

Issue:

When running the CAIRIM (CAS9) process for CA Datacom version 14.0, the process for one of the sets of control statements ends with an Init error and RC=0008, and displays a message about SYNTAX ERROR(H):

CAS9115I - Input: PRODUCT(CADATACOM) VERSION(BD14) INIT(DBCR4PR) LOADLIB(…)
DB90150I - DATACOM DBCR4PR  2011/03/18-1055 14.0
DB90154I - DATACOM DBPCCPR  2015/04/12-1226 14.0 RO80232
DB90152E - DATACOM PARM SYNTAX ERROR (H)
DB90153E - DATACOM INITIALIZATION FAILED
CAS9140E - Init error: CADATACOM            Ver BD14, Init routine RC=0008
CAS9115I - Input: PRODUCT(CADATACOM) VERSION(BD14) INIT(DBCR4PR) LOADLIB(…)
DB90150I - DATACOM DBCR4PR  2011/03/18-1055 14.0
DB90154I - DATACOM DBPCSPR  2013/04/19-1254 14.0 RO56818
DB90151I - DATACOM INITIALIZATION SUCCESSFUL
CAS9130I - Module DBCR4PR  complete, RC=00

Environment: 

This applies to CA Datacom/AD and CA Datacom/DB at version 14.0.

Cause:

In version 14.0, the initialization process now loads two different Program Call modules to handle cross-memory communication with applications. These two modules are called DBPCCPR and DBPCSPR, and are loaded based on the keywords, PCC= and PCS=, respectively.

If the wrong keyword is used for a module, i.e., if PCC=DBPCSPR or PCS=DBPCCPR, the initialization will fail and produce this SYNTAX ERROR (H).

Resolution:

Review the two sets of control statements to be sure that the PARM= value has PCC=DBPCCPR and also PCS=DBPCSPR.

As always, please contact CA Technologies support for CA Datacom if you have further questions.

 

Environment

Release:
Component: DB