MSP Superuser is receiving VCO error "Cannot set property 'v6Detail' of undefined" while adding BGP community values in partner handoff. No configuration can be made and saved for partner gateway handoff when MSP superuser attempts to make the changes. We are referring to the Partner hand off section found within the enterprise's Global Settings > Customer Configuration > Gateway Pool.
VECO with a tenant that has partner gateway handoff configuration.
This behavior is occurring because the BFD default value has been removed from the configuration update that is made when we try to save the configuration as MSP user for partner gateway handoff configuration. This is a defect that is being tracked through defect ID #154008.
Defect ID #154008 is targeted to be fixed on VCO build 6.4.x.x. A workaround for this behavior would be to have a user with operator access to make and save the configuration changes for partner gateway handoff configuration. If this is a Broadcom managed VCO, you would need to open a support ticket to have a support engineer assist with those changes as they will have operator access.